To introduce you to switch products manufacturers how to use correctly
1. When the switch manufacturer introduces the fixed switch body, use a small screw of the M2 to fix it on a smooth surface with a torque of 0.098 N · m or less. In addition, to prevent loosening of the screws, it is recommended that the washers be used at the same time.
2. Please note that the free body action should not be directly applied to the button or the actuator force, the use of the button should be applied in the vertical direction of the force.
3. The operation setting after the action is set to 70 [%] or more of the O.T. value. Switch, do not set the operating body in the action limit position, so as to avoid the impact of the opening and closing, over-stroke to shorten life.
4. Switch manufacturers introduce changes in the operating characteristics.
A change in operating characteristics shall not cause a fault even if a change in the operating characteristic specification value of ± 20 [%] occurs.
5. On the welding operation.
When using manual soldering, please use an electric temperature of 320 ° C max. With temperature adjustment.) Perform the work within 3 seconds, and do not apply force to the terminals during operation.
6. It is recommended to use low power circuit type Au cladding contact when using under small current and voltage.